On Tue, Jan 4, 2011 at 5:21 AM,  <dbellw...@aol.com> wrote:
> I switched computers and now, just getting N1MM on screen causes the K3 to
> transmit.  The K3 works as usual with N1MM off and vice versa.  Phone  or
> CW, VOX on or off, no matter.  When N1MM and the K3 are on together, the  K3
> is in transmit.

Two ways to fix this (pick one).

* In N1MM Logger, Config ->Configure Ports -> Hardware , click the
"Set" button next to the K3's COM port and change DTR and RTS to
"Always Off".

* On the K3, set CONFIG:ptt-key to "off-off"

Alternatively, you can actually use the RTS and DTR lines on the COM
port for PTT and CW keying, if you want, by configuring them to match.

    ~Iain / N6ML