On my newly assembled kit K3/10 without the internal ATU, I've noticed that the SWR readouts are "higher" than those on my K2 which agrees with my analog inline meter. Into a 50 ohm dummy load all three readings are 1.0:1, but on an actual antenna the readings differ.
For example, where my K2 and the analog meter read 1.4:1, the K3 says 1.9:1. this variance increases as the SWR increases and decreases as the actual SWR decreases, hence the agreement among all three measures on 1:1 when operating into a dummy load. All readings taken at 5 watts, same antenna, same SG-237 autocoupler, same cable routings, and the internal ATU in the K2 bypassed. The only variable is the actual 48"coax jumper going from the K3 to the patch panel. I just finished the K3 yesterday so I am just a K3 beginner. However I could find nothing in the manual about SWR calibration. Any pointers would be appreciated. Other than this, everything appears to be working great and the K3 DSP is fabulous. Stan WB2LQF K3 #5244 ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html