Thank you, Jim, and yes, I can confirm that I am getting the phenomenon. I can't say that I had come across the problem previously. In fact it's quite a useful feature in that it reinforces the fact that the K3 is locked even when looking at other Config Tech settings. In some ways, I hope that Elecraft do not correct the minibug ;-)
73 de David G4DMP In a recent message, Jim Sheldon <w...@cox.net> writes > >David, >The exact conditions the anomaly occurs under are: Tech mode ON, >external reference 10 MHz signal connected and operating, go to MENU >CONFIG, REF CAL (only available with tech mode on) and watch for the >blinking asterisk. If it is NOT blinking, the problem won't appear. >While the asterisk is blinking, use the VFO B control and go to any >other menu item that has at least 4 letters in the VFO B portion of the >display. The 4th one will blink (same display position that the >asterisk was in) and continue to do so in any other menu item that has >at least 4 letters displayed in the VFO B window (only that window). >Once you exit the MENU CONFIG mode, the blinking will stop and not re- >occur until you again display REF CAL long enough to see the blinking >asterisk. > >It does not affect the performance, only the display as far as I can determine. -- + - - - - - - - - - - - - - - - - + | David M Pratt, Kippax, Leeds. | | Website: http://www.g4dmp.co.uk | + - - - - - - - - - - - - - - - - + ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html