Couldn't this be automated for those with the K3EXREF? Since the K3EXREF is applying a "fudge factor" (technical term) based on the instantaneous error of the 49 MHz TXCO, one could "simply" read the correction and the front panel temp over a thermal "run". The data could then be massaged (another techinal term) internally, to come up with the tabular data needed. Yes?
Bruce, N1RX Wayne, N6KR wrote: > What we could do in a future release is provide a way for customers to > manually generate and use 1-degree data. Call it "Method 4." It seems > a bit onerous, but here's the idea: First, you'd put your K3 in the > refrigerator long enough to get to 0C, or the desired low operating > temp. Next, set the rig up with an accurate frequency counter > connected to the output of the oscillator, and put the cover back on, > or at least part of the way on (the freq counter cable has to come out > at the back or side). Then, as the radio heats up, write down the > oscillator frequencies for each 1-degree point. <snip> ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html