Just checking...
I get about 7.6 A at about 62 volts when on 75M putting out about 350 watts.
I get about 0.4 A keyed with no rf input. Is that about right?
Just wondering if these are normal values. A friend on 75M says he can
detect something...on my voice sometimes...when doing about 350 watts with
15 watts input. He  cannot hear any "issues" barefoot. No one else in the
QSO can hear anything but clean signal. I thought maybe just a tiny bit of
rf in the audio...or morning voice. But the amp works flawlessly. About 25
watts takes it to 500 watts output, etc. I am at the high tap for high line
voltage. Set to 120 vac...and at 500 watts output it shows right about 60
supply volts.
Just wondering if maybe he has 4-1000 prejudice against solid state
linears...:) 

-----
Chuck, KE9UW
--
View this message in context: 
http://elecraft.365791.n2.nabble.com/KPA500-operating-current-values-tp6751150p6751150.html
Sent from the Elecraft mailing list archive at Nabble.com.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to