Just when one thinks all is good in the world... I re-worked a Hustler 5BTV so 
that it covers 40-30-20-15-10 meters, rather than 80-40-20-15-10. The mod was 
simple - cutting off five inches from the top tube. No problem. It now has a 
1.1:1 SWR across most of the bottom of 40 meters. Sweet. Kinda.

When I crank my KPA500 up to full output on 40 meters, I get RFI on my home 
security system. Lights up all the remote panel lights and beeps. Luckily it 
does NOT set off the alarm. If I back off output to 350 watts or so, no RFI 
problem. Both ends of my RG-8 coax have ferrite chokes. This problem ONLY 
happens on 40 meters; full power on any of the other bands causes no issues. 

The vertical is mounted on the ground, 25 feet away from the house, with about 
40 fairly short radials. The security system controller (an Ademco 4150, 21 
years old) is in a metal case, and is located in a closet on the second floor 
of the house.

Anyone else have RFI problems with their security system? If so, how were you 
able to cure it? I was thinking that perhaps ferrite beads on every lead coming 
into the controller box may do it?

Tnx, Jim / W6JHB
Folsom CA