Hi All,
To echo Jim Brown's cautionary statement about IMD with the RM Italy HLA
series amps, there is some good info on Tom Rausch's (W8JI) website
concerning the HLA-150. That amp will run up to 150 watts or so, but
according to some testing that Rausch did, if you go much over 100 watts,
the IMD gets pretty marginal! Presumably the HLA-300 have some similar
optimal point below it's maximum capability. Apparently this is not at all
uncommon, particularly with 12 V. amps. Even the K3 loses some of it's IMD
quality if you go over 100 watts, which you can do somewhat.