Andy,

D1 is necessary to provide AGC and S-meter indication.

I suspect the owner who lifted the end of D1 wanted AGC OFF all the time.
AGC OFF is available as a 2 button hold (PRE/ATT and AGC) from the front panel, but it does not survive a power off cycle.

I would think you should reconnect it.

73,
Don W3FPR

On 5/26/2013 8:50 AM, Andy McMullin wrote:
Hi All,

I acquired my K2 pre-loved (second-hand) and it seems to be working just fine.

However, today I started working on installing a new option into it and I 
noticed that the diode D1 on the control board has been disconnected at one end 
(but left soldered in at the other end - so it hangs off the board).

Can someone enlighten me as to why this might have been done? I've looked 
through the manuals and haven't spotted it as a step in fitting any of the 
options.

Thanks in advance.


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to