Scotty,
The most common cause for that behavior is a problem with T1 - leads not
adequately stripped and tinned, leads not in the correct holes, the
toroid wound in the wrong direction (it must be *exactly* like the
figure in the manual), inadequate soldering.
One other (but less common) cause is for there to be a capacitor or
inductor that is being left in the circuit. The normal cause of that is
missing a solder connection to one of the relays or the firmware IC.
73,
Don W3FPR
On 10/5/2013 6:10 PM, Scotty Long wrote:
Just installed NB works great.
Newly installed KAT1 page 9 no appreciable value change volts when adjusting
C9...
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html