Scotty,

The most common cause for that behavior is a problem with T1 - leads not adequately stripped and tinned, leads not in the correct holes, the toroid wound in the wrong direction (it must be *exactly* like the figure in the manual), inadequate soldering.

One other (but less common) cause is for there to be a capacitor or inductor that is being left in the circuit. The normal cause of that is missing a solder connection to one of the relays or the firmware IC.

73,
Don W3FPR

On 10/5/2013 6:10 PM, Scotty Long wrote:
Just installed NB works great.

Newly installed KAT1 page 9 no appreciable value change volts when adjusting 
C9...



______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to