AH, that did it! Thanks for the help -- I was missing that second tap to
get out of Menu.
Now, I'm seeing 5.6 volts on PLL1 and 2.9 on PLL 2.
Not sure what the tolerance range is but maybe we've lost some
regulation of PLL1's voltage?
73/Jon AA1K
On 10/14/2013 9:54 PM, Sam Morgan wrote:
once you have set CONFIG: TECH MD to ON
then tap the [MENU] button to get out of CONFIG
now tap [DISP]
(to make VFO B show various items, like voltage, current, PA temp, etc)
turn VFO B knob
until you see PLL 1 #.#
or until you see PLL 2 #.#
the #.# is actually the voltage reading
example
my PLL 1 shows 3.0
my PLL 2 shows 3.2
On 10/14/2013 8:16 PM, Jon Zaimes AA1K wrote:
Trying to debug two problems in one of my K3 receivers. Not sure if they
might be related and just starting to delve into it.
The main RX works fine for several minutes (although the sub RX seem to
lack sensitivity) and then the main RX loses signals (although the
background hiss seems constant) and I see ERR PL1. When I try the
troubleshooting procedure in the manual:
"VPLL out of range on band change (to view
actual PLL voltage, set CONFIG: TECH MD
to ON, then tap DISP and use VFO B to locate
the PLL1 and PLL2 voltage displays)."
This procedure goes OK but after I hit DISP the screen shoes "<OFF> SHOW
TECH--MODE MENU ENTRIES, TAP 1/2 ..." but if I tap "1" or "2" it just
shows "FFFF" at top of screen for either one. What does this mean?
73/Jon AA1K
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html