Try a parameter initialization. While holding the LABELS key, tap the POWER switch, which will turn the P3 on if it was off. After about 2 seconds you should see "CONFIGURATION RESET" on the screen and you can release the LABELS key.

Alan N1AL


On 06/24/2014 08:33 PM, Hisashi T Fujinaka wrote:
Well that was pleasant. I was making a band change (chasing W1AW/3 and
W1AW/9) and my P3 with P3SVGA went into a screen that said something
like "Ready to load Firmware." I tried to load the firmware but at the
power-cycle I got the screen:

=====

****  FATAL ERROR  ****
In: ddc_set_coef()
span=0

Press any active key to escape

=====

I tried again, and the same screen appeared.

None of the keys did a thing. So I power cycled again and saw the same
screen. I thought removing the P3SVGA might help but reloading and
resetting gave the same error.

What next?

Thanks.