All excellent replies, thanks to all. Right now I have the vga cable with two
loops through a large snap-on of unknown mix (I have just ordered a couple
of large 31 mix snap-ons) and placed seven snap-on beads of unknown mix on
the AC cable. It looks like the situation is better as it now requires about
a five second keydown to freeze the monitor, (not something that happens a
lot, just a test.) I tried swapping the small beads on the AC line with a
double loop through a snap-on (like the one I now have on the vga cable) but
that was much worse. 

Regarding keeping RF out of the shack, Don, the 40/80 meter inverted vee has
a several looped coax choke at the center feedpoint and the SteppIr vertical
has a large DX Engineering one-to-one balun/choke. The Mosley 2 element Yagi
has a common mode choke made of a string of beads originally used for a
Spyderbeam. The coax feedlines are all between 75 and 100 feet. I will look
into more suppression at the shack entrance.

And Bryon, I will check to see if the BenQ mounting holes (I am using
mounts) are connected to the D-shell.

Thanks.  ..mike  AI6II



--