The standards go thusly.

TIA/EIA 568-A (T568A)

Pin 1 - white / green stripe

Pin 2 - green

Pin 3 - white / orange stripe

Pin 4 - blue

Pin 5 - white / blue stripe

pin 6 - orange

pin 7 - white / brown stripe

pin 8 - brown


TIA/EIA 568-B (T568B)

Pin 1 - white / orange stripe

Pin 2 - orange

Pin 3 - white / green stripe

Pin 4 - blue

Pin 5 - white / blue stripe

Pin 6 - green

Pin 7 - white / brown stripe

Pin 8 - brown


568B is predominant in the US. If you're making patch cables use the same standard on both ends. If you're making a cross over cable use the "A" on one end and the "B" on the other. It really doesn't matter if you use a standard or not as long as both ends are identical...that is until someone else works on your network. I spent a week rebuilding 50 CAT6 runs that someone decided to use their own standard on.

I've got 'em memorized. I can also subnet IPv4 in my head.

I need a hobby.;-)



On 5/1/2016 9:53 PM, Byron Servies wrote:
There are 2 wiring standards for cat5/5e/6 cable into RJ45 style modular
plugs: EIA/TIA-568A and EIA/TIA-568B (aka T568A and T568B). They are
slightly different, and both work to gigabit speeds. You can mix them, but
in a data center, for example, they will try to stick with 1 or the other.


73, Byron N6NUL



--
R. Kevin Stover
AC0H
ARRL
FISTS #11993
SKCC #215
NAQCC #3441



---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com

Reply via email to