> -----Opprinnelig melding----- > > An example of this is I turn the rig on and say it comes up > on 14.010. I tune up the band to 14.035 and turn it off. If > I turn it back on immediately, it come up back on 14.010!
Did you try to wait > 30 seconds before you turn it off? The manual says: "Backup Timer While you're moving the VFO, a 30-second data backup timer is being continuously re-started. Once you have completely stopped tuning the VFO for at least 30 seconds, the K2 will then save your current operating frequency in EEPROM. As long as you stay on a particular frequency, no further updates will be done." 73 Sverre LA3ZA http://www.qslnet.de/la3za/ _______________________________________________ Elecraft mailing list Post to: Elecraft@mailman.qth.net You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com