> -----Opprinnelig melding-----
> 
> An example of this is I turn the rig on and say it comes up 
> on 14.010.  I tune up the band to 14.035 and turn it off.  If 
> I turn it back on immediately, it come up back on 14.010!

Did you try to wait > 30 seconds before you turn it off?

The manual says:

"Backup Timer

While you're moving the VFO, a 30-second data backup timer is
being continuously re-started. Once you have completely stopped
tuning the VFO for at least 30 seconds, the K2 will then save your
current operating frequency in EEPROM. As long as you stay on a
particular frequency, no further updates will be done."


73

Sverre
LA3ZA
http://www.qslnet.de/la3za/
 