How did you determine that the cables seem "fine".
Did you do a continuity measurement on each pin? Did you check for shorts between adjacent pins.

If selecting 12 meters on the K3 produces 6 meters on the KPA500, then there may be something awry with the BAND1 data output from the K3 to the KPA100. That is pin 3 of the cable.

73,
Don W3FPR

On 8/3/2016 8:12 PM, Harlan Sherriff wrote:
Both cables seem ok. Also, if I select 12m on K3, the KPA goes to 6m. I'm just 
a little confused.



______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com

Reply via email to