How did you determine that the cables seem "fine".
Did you do a continuity measurement on each pin? Did you check for
shorts between adjacent pins.
If selecting 12 meters on the K3 produces 6 meters on the KPA500, then
there may be something awry with the BAND1 data output from the K3 to
the KPA100. That is pin 3 of the cable.
73,
Don W3FPR
On 8/3/2016 8:12 PM, Harlan Sherriff wrote:
Both cables seem ok. Also, if I select 12m on K3, the KPA goes to 6m. I'm just
a little confused.