Dave,
Check the ACC cable at the K3 end. I suspect one of the wires in the
transverter control cable is touching the DE-15HD connector pin 8
(Remote Power ON).
73,
Don W3FPR
On 8/6/2016 12:26 PM, Dave Fugleberg wrote:
Still trying to sort out my transverter problem - see my first post on that
today. I have only the transverters connected to the K3. When I connect
power to the rig runner, the k3 tried to power on by itself and displays
'turn on KAT 500'. I don't even have one, but I do have a P3, which is not
connected at this point.
I vaguely recall seeing that message when I first got my P3, and finding a
solution, I don't remember what it was.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]