Hi Dan,

You can go into the AGC SLP menu and then do a sequence of UP; and DN; commands 
to arrive at your final value.  The strategy for these types of macros is to 
drive the parameter to one end, e.g. 15 UP; commands set SLP=15 and then 5 DN; 
changes it back to 10, if that's the value you want.


Cheers,

Fred KE7X

________________________________
From: Dan Atchison <n...@aol.com>
Sent: Thursday, February 23, 2017 8:30 AM
To: Cady, Fred
Subject: Slope Macro Settings

Hi Fred:

You wrote:
"BTW, it is easy to make macros to switch between different THR/SLP values for 
different operating conditions."

I see how you can write a macro to set Threshold settings, but how is that done 
with Slope settings?