Just to update on this thread: repeating the calibration on 10MHz with 13.8V applied does get to 4/6W indicated on the VFO B display, but on tapping XMIT, still gives ERR TXG (D=228 or thereabouts on the main bit of the display). I'll drop Elecraft an email.
73, Rob, M0VFC On 18 April 2017 at 13:07, Don Wilhelm [via Elecraft] < ml-node+s365791n7629474...@n2.nabble.com> wrote: > Rob, > > I would try running the TX Gain Calibration with a higher voltage power > source - at least 13.8 volts. > > If it still fails, contact Elecraft support. > > 73, > Don W3FPR > -- View this message in context: http://elecraft.365791.n2.nabble.com/Low-power-out-ERR-TXG-when-trying-to-calibrate-power-tp7629471p7629508.html Sent from the Elecraft mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com