Just to update on this thread: repeating the calibration on 10MHz with
13.8V applied does get to 4/6W indicated on the VFO B display, but on
tapping XMIT, still gives ERR TXG (D=228 or thereabouts on the main bit of
the display). I'll drop Elecraft an email.

73,
Rob, M0VFC

On 18 April 2017 at 13:07, Don Wilhelm [via Elecraft] <
ml-node+s365791n7629474...@n2.nabble.com> wrote:

> Rob,
>
> I would try running the TX Gain Calibration with a higher voltage power
> source - at least 13.8 volts.
>
> If it still fails, contact Elecraft support.
>
> 73,
> Don W3FPR
>




--
View this message in context: 
http://elecraft.365791.n2.nabble.com/Low-power-out-ERR-TXG-when-trying-to-calibrate-power-tp7629471p7629508.html