OK - I check this again after moving the board off my antistatic mat and
onto the manual, and power cycling the multimeter, and how I'm getting 3.6k
ohms at this point.  So all OK.  Not sure what this issue was that moving
the board or power cycling the MM solved.

Mark  W8EWH

On Sun, Apr 21, 2019 at 8:54 AM Mark Yergin <mark.yer...@gmail.com> wrote:

> I'm on the Page 62 Resistance Check and R115 / 12V IIN check should be
> >500 ohms and I'm getting 132 ohms.  All other checks in the table are fine.
>
> Before I move on to Alignment and Test Part 2, I want to get some feedback
> on this discrepancy.  Move on? Or what does this indicate I should be
> checking?
>
> Mark W8EWH
>
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to