Thanks for all the quick replies.

The data is at http://www.hascorelays.com/electro_klt_series.asp.

The dielectric strength between open contacts is specified at 750VAC 
(50/60Hz). Guessing that the dielectric is air and air has a breakdown 
voltage of about 3KV/mm that equates to a contact spacing of about 0.25 mm.

Wow that seems very small. Have I figured this wrong?

Darrell

On July 6, 2006 03:09 pm, [EMAIL PROTECTED] wrote:
> KLT1C12DC12 made by Hasco
>
> Michael
> N2ZDB
> _______________________________________________

-- 
Darrell Bellerive
Amateur Radio Stations VA7TO and VE7CLA
Grand Forks, British Columbia, Canada
_______________________________________________
Elecraft mailing list
Post to: Elecraft@mailman.qth.net
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft    

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to