"We are constantly getting the "270V ERR" when switching over to OPER.  We have 
checked that the micro-switch is working properly and is correctly operated by 
the lid."

If it were mine I'd measure the voltage and ask for the low and high warning 
levels.   Of course you must take proper precautions.  There is a reason there 
is an interlock switch. 

My KPA 500 notes include this:

"Investigation revealed
the PSU board multiplier could produce 210V OFF LOAD with the PSU>LPF jumper
disconnected but only 60v when the jumper was connected. Simulating the pin
diode current consumption with a resistor also produced the same result.
Turned out that R16 which should have been 100 ohm was now 1.2Mohm.
Replacing it fixed that problem

While talking to elecraft support it transpired that there was an upgrade
kit (E850607) that replaces the Q5 FET on the LPF board with a transistor
(as usual no reference could be found to it on the elecraft web site!). This
upgrade has also now been done"

I regret that I did not record the source.

Andy, k3wyc
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Reply via email to