On 2021-01-04 4:07 PM, Rick NK7I wrote:
> While I don't have the Microham, the Y should be first in the series
> (listen only port to the Microham);

*NO!!!*  The microHAM USB III is, in part, a USB to Serial converter.
It provides the CAT connection to the transceiver and should be treated
as a computer serial port.  The RS232 connection should *NEVER* be
attached to a "listen only" port on a "Y" cable.

73,

   ... Joe, W4TV


On 2021-01-04 4:07 PM, Rick NK7I wrote:
While I don't have the Microham, the Y should be first in the series (listen only port to the Microham); to the P3, then the cable from the P3 to the K3 so they can 'chat'.  (That is the same as I do for my SteppIR controller.)

HNY,
Rick NK7I


On 1/4/2021 12:28 PM, MICHAEL SMITH wrote:
Gentlemen:

I recently purchased a P3 and connected it to my K3.  The installation shares the RS232 connection with a Microham USB interface III for digital operation.  I used a Y cable to connect both of these units simultaneously.

I find I cannot run both at the same time.  If I do, the P3 does not display the frequency at the top of the screen, and does not display the band-pass of the VFO A.  Each unit will run separately with full function.

Has anyone else experienced this interaction?  Were you able to adjust the connection to allow full function of both units?  How did you do it?

73, Mike Smith
K0CCM


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com 

Reply via email to