On 30/05/2021 19:42, elecraft-requ...@mailman.qth.net wrote:
The problem could be solved with a toggle switch in the shack opening the PTT
line, but not for remote. Thus my question of whether it is possible to get
RF from the K3 w/o activating PTT.
I wonder if the DIGOUT1 output of the ACC connector can be made to do
what you want: drive a relay that interrupts the KEYOUT line.
Alternative (and perhaps more expensive): The KPOD has 3 outputs that
can be switched using serial commands. If you try this, be aware that
the documentation of the KPOD is (or was) wrong: tip is output3, not
output1, and vice versa.
If you want to use this to drive a relay you probably want a PNP
transistor as buffer.
73, Geert Jan PE1HZG
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com