To follow up on my question about the PLL range test, how critical is it to be 
at or below 15Khz? Currently I am at 15.40Khz after playing around with the 
winding spread. The errata sheet says to be between 9.98Khz and 15Khz 
difference in the high and low reading.

73
James, KJ4KEM


> On 11/04/2021 7:57 PM Comcast <gun...@comcast.net> wrote:
> 
>  
> Hello again,
> Still building a K2. I got to the PLL reference oscillator range test and did 
> have to remove one turn from the toroid.My range at first was 20.6 Khz.
> I got it down to 15.38Khz. I am worried if I remove another turn it will be 
> too low. I went ahead with the continued testing and all the numbers (test 
> results) are good.
> I stopped for the night on the BFO alignment.
> My questions is, is the 15.38Khz ok or do I need to remove another turn from 
> the toroid?
> 
> 73 
> 
> James, KJ4KEM
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:Elecraft@mailman.qth.net
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to gun...@comcast.net
______________________________________________________________