Good evening everyone,
I have just completed RF assembly part II and started the alignment and test when right off the bat I have a problem. The "4 MHz Oscillator Calibration" step 3 on page 60 states "the counter should show a frequency of 12090 kHz +/- 30 kHz". Well mine reads 12600. Searching the archive I found plenty of examples of the PLL reference oscillator range test but nothing about not getting the wrong reading. I checked the freq probe by testing and finding 4000.00 at C22. Any suggestions on where to start troubleshooting. Thanks Terry VA6MAC K2 s/n 5567 ************************************************************************ This e-mail message is intended only for the person(s) named above and may contain confidential or privileged information. If you are not the person named or have not been authorized by them to access their mail, please notify the sender immediately and delete this e-mail and any attachments without reading, saving, or forwarding. ************************************************************************ _______________________________________________ Elecraft mailing list Post to: Elecraft@mailman.qth.net You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com