At 02:12 PM 12/14/2006, Howard W. Ashcraft wrote...
For an example of what damage can be done, I am restoring a Tek SC504 oscilloscope where someone used contact cleaner/solvent on the channel 2
attenuator.

Tek used special PC board material (polysulfone?) in the attenuators for many of their scopes. Most of the manuals specifically warn about using anything other than isopropyl alcohol for cleaning.

From the 485 manual - "Cleaning the switch contacts should only be done using isopropyl alcohol or a solution of 1% Joy detergent and 99% water. Do not use acetone, MEK, MIBK, benzol, toluol, carbon tetrachloride, trichlor, trichlene, methyl alcohol, methylene chloride, sulfuric acid, or Freon TC-TETF-22-TA-12." - they had a sense of humor, no battery acid cleaning allowed!
_______________________________________________
Elecraft mailing list
Post to: Elecraft@mailman.qth.net
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com