Hi, David: T3 has 5 bifilar turns as shown in Figure 67 of page 71 of the Rev G manual. That's a very old photograph (Figure 8 Appendix D) that appears to have been left over from the K2 beta test days almost a decade ago! It's in my 2000 vintage K2 manual too, even though T3 was already a 5 turn transformer by then.
Thanks for mentioning it. It goes on the "fix that!" list <G>. Ron AC7AC -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of David Woolley Sent: Wednesday, August 01, 2007 3:53 PM To: elecraft@mailman.qth.net Subject: [Elecraft] K2: Number of turns on T3: text and photo disagree I've wound T3 with 5 turns, but I found I had a lot of wire left over and examination of the photographs in the manual suggest that the T3 in the specimen assembly has 10 or 11 turns. Is 5 turns correct? -- David Woolley _______________________________________________ Elecraft mailing list Post to: Elecraft@mailman.qth.net You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com