Elecraft says.....
"Some owners prefer a faster CW keying waveform rise time. The rise time
can be reduced from about 8 milliseconds to 5 milliseconds without
affecting the fall time by replacing capacitor C222 on the K3 main RF
board with a 0.1 uF capacitor. This change will also allow a future
firmware revision to further reduce rise time via a menu entry."
But the schematics of the RF Board Rev. A4 (Sheet 3 of 4), dated
9/19/07, show C222 as being 0.1 already. The instructions recommend
removing the existing 0.1 and replacing it with another 0.1 !! Surely
to reduce the rise time the existing capacitor should be shunted with
another one.
Or do Rev A RF boards have a lower value for C222 than that shown on the
schematic?
73
--
David G4DMP
Leeds, England, UK
_______________________________________________
Elecraft mailing list
Post to: Elecraft@mailman.qth.net
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com