I'm still trying to debug my problem with the Top Ten band decoders and my K3 (s). When I put a volt meter on the band data output pins of the K3's ACC connector, I don't see any positive voltage (all the pins read zero). When I connect the ACC pins to the Top Ten decoder via an appropriate cable (thus bringing the decoders pull-up resistors into the picture), I see a non-zero voltage on the "high" pins, but only between 1.6 and 2.2 volts - not 5 volts. Without the connection to the K3 in place, the same pins measure 5 volt (due to the pull-ups).
Is this normal - in particular, is it normal not to be able to measure a positive voltage on the "high" pins of the ACC connector with nothing other than the meter attached? I realize that these are "open collector", but I would have expected to read some positive voltage. ***dan, K6IF _______________________________________________ Elecraft mailing list Post to: Elecraft@mailman.qth.net You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com