I am sometimes finding it will read 1 bar above what it should, which is what you are seeing. But using the AT1 step attenuator, I find that it takes only 1 or 2 dB attenuation to bring the reading down one bar. This now one heck of an accurate S meter. I now have within a couple of dB at the S3, S9 and s9+40 calibration points that I can do without fiddling with the attenuator.
ab2tc - KNut David Pratt-4 wrote: > > I have just completed a full recalibration of Power and the new S-meter > calibration with successful results. I am most impressive. > > One query though... Using the SG1 to generate a 1uV and 50uV signal > source on 7040kHz, after calibration I find that the S-meter reads > S9+5db with 50uV and S4 with 1uV. This is with both the main RX and the > Sub RX. Is that what others find? > <snip> > ----- AB2TC - Knut -- View this message in context: http://n2.nabble.com/K3%3A-New-Utility%3A-S-meter-calibration-tp3437484p3440890.html Sent from the Elecraft mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html