Hello dear Electric developers,

I found problems using Technology Wizard.

= 1st issue =

For Via1 in Design Rule Manual I have the following DRC rules:
  o M2.E.1 Minimum extension of a M2 region beyond a VIA region C=0.15um
  o VIA1.E.1 Minimum extension of a M1 region beyond a VIA1 region C=0.20um

I can't set rule M2.E.1 in Electric Tech. Wizard

For Via2 I can't set rule M3.E.1 (minimum extension of a M2 region
beyond a VIA2 region)

= 2nd issue =

I would like rename layer "Device Mark" to "Frame" or "prBoundary" or
smth else. Could you please make ability to rename layers by user in
Tech. Wizard.


--
Yours sincerely,
   Artem

--