Hi Gilda, I changed my technology to have just one layer (a metal layer). Still having issues with DRC. Am getting the same bug. I spent some time checking out if DRC works for other technologies (eg) the built-in nMOS technology. Am having trouble with that.
Have copied below notes from previous users in the group showing the same issue... https://groups.google.com/d/msg/electricvlsi/1Cj3Oa9DnbM/ALLNOVRzQoYJ Thanks for your help once again, Deepak On Thursday, August 16, 2012 4:51:10 PM UTC-7, Deepak Sekar wrote: > > Hi Gilda, > > I tried loading the DRC rules, and it didn't work. Attached is the DRC > file I loaded just to check this out. > > You can try some arbitrary value and check it out if you want... for > example, you could try minimum metal width to be 2.4um (2 lambda) > > Thank you, > Deepak > > On Thu, Aug 16, 2012 at 4:28 PM, gildav <[email protected]> wrote: > >> Deepak >> >> The xml tech doesn't have any drc rule so I don't see how it could have >> reached the code in the exception below (at least with the simple example I >> created) >> >> Gilda >> >> Deepak Sekar wrote, on 8/15/12 2:58 PM: >> >> Hi Gilda, >> >> Thanks for helping out. >> >> Attached is the xml file for my new technology. >> >> Deepak >> >> >> >> >> >> ------------------------------------------------------------------------------------------------------------- >> On Tuesday, August 14, 2012 10:08:25 AM UTC-7, Gilda wrote: >>> >>> Deepak >>> >>> Can I have access to your new tech? The exception below might suggest >>> that something is not OK with it. >>> >>> Thanks >>> >>> Gilda >>> >>> Deepak Sekar wrote, on 8/13/12 4:45 PM: >>> > Hi, >>> > >>> > I've created a new technology by editing the existing nMOS technology >>> > in Electric. I'm unable to run DRC on it though, it says "Exception >>> > caught" and gives me the following error message. Has anyone >>> > encountered this issue yet? Any countermeasures? >>> > >>> > Thank you, >>> > Deepak >>> > ------------------------------**------------------------------**------------------ >>> > >>> >>> > Running DRC with area bit on, extension bit on >>> > Checking again hierarchy .... (0.0 secs) >>> > Found 10 networks >>> > Checking cell 'nmos{lay}' >>> > java.lang.AssertionError >>> > at com.sun.electric.tool.drc.DRC.**cropActiveArc(DRC.java:106) >>> >>> > at com.sun.electric.tool.drc.**Quick.checkArcInst(Quick.java:* >>> *855) >>> > at >>> > com.sun.electric.tool.drc.**Quick.checkThisCell(Quick.**java:547) >>> >>> > at com.sun.electric.tool.drc.**Quick.doCheck(Quick.java:336) >>> > at >>> > com.sun.electric.tool.drc.**Quick.checkDesignRules(Quick.**java:157) >>> >>> > at com.sun.electric.tool.drc.DRC$** >>> CheckDRCHierarchically.doIt(**DRC.java: >>> > 1465) >>> > at com.sun.electric.tool.EThread.**run(EThread.java:117) >>> > >>> >>> -- >> You received this message because you are subscribed to the Google Groups >> "Electric VLSI Editor" group. >> To view this discussion on the web visit >> https://groups.google.com/d/msg/electricvlsi/-/wP0Iwe08y-sJ. >> To post to this group, send email to [email protected]. >> To unsubscribe from this group, send email to >> [email protected]. >> For more options, visit this group at >> http://groups.google.com/group/electricvlsi?hl=en. >> >> >> -- >> You received this message because you are subscribed to the Google Groups >> "Electric VLSI Editor" group. >> To post to this group, send email to [email protected]. >> To unsubscribe from this group, send email to >> [email protected]. >> For more options, visit this group at >> http://groups.google.com/group/electricvlsi?hl=en. >> > > -- You received this message because you are subscribed to the Google Groups "Electric VLSI Editor" group. To view this discussion on the web visit https://groups.google.com/d/msg/electricvlsi/-/3BE5SEu7nB0J. To post to this group, send email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit this group at http://groups.google.com/group/electricvlsi?hl=en.