Bugs item #2700511, was opened at 2009-03-21 07:45
Message generated for change (Tracker Item Submitted) made by wildrice
You can respond by visiting: 
https://sourceforge.net/tracker/?func=detail&atid=106744&aid=2700511&group_id=6744

Please note that this message will contain a full copy of the comment thread,
including the initial issue submission, for this request,
not just the latest update.
Category: EMC2 Installation, packages
Group: None
Status: Open
Resolution: None
Priority: 5
Private: No
Submitted By: Chuck Rice (wildrice)
Assigned to: Nobody/Anonymous (nobody)
Summary: Machine Configuration setup for Sherline Incorrect

Initial Comment:
EMC2.2 Dapper install on a Sherline CAD system. 

When you setup your "Driver type" in the "Machine Configurations Page" and 
choose Sherline you get wrong settings for the stepper motors.
The "Step Time" and "Step Space" should be inverted.
They want "Step Time" to be 1000, but it should be 6000. "Step Space" is 6000 
but it should be 1000.

Swapping these two values fixes the problem. 

Thanks to Telle for discovering this bug!

----------------------------------------------------------------------

You can respond by visiting: 
https://sourceforge.net/tracker/?func=detail&atid=106744&aid=2700511&group_id=6744

------------------------------------------------------------------------------
Apps built with the Adobe(R) Flex(R) framework and Flex Builder(TM) are
powering Web 2.0 with engaging, cross-platform capabilities. Quickly and
easily build your RIAs with Flex Builder, the Eclipse(TM)based development
software that enables intelligent coding and step-through debugging.
Download the free 60 day trial. http://p.sf.net/sfu/www-adobe-com
_______________________________________________
Emc-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-developers

Reply via email to