I ran across this same bug jogging W, so I presume it affects U & V.
And W was a real x25.4 velocity increase, good thing it was slowed.
This was while running (Axis) in metric mode. (G21 and "display mm".)

Kim


On 01/15/2013 02:26 AM, Chris Morley wrote:
> 
> While doing work on Gscreen, I was testing AXIS and noticed
> in the 9 axis sample if you set it to display metric (it's an imperial
> machine) the velocity of the angular axis is displayed 25.4 too much.
> 
> Degrees are being converted obviously.
> I would think this is a bug....
> 
> Chris M
>                                         
> ------------------------------------------------------------------------------