i'm trying to organize my configs and having trouble doing it
conveniently. i'd like to localize external connections in one place
and give signals meaningful names. e.g.

net x-neg-limit sscii.0.gpio.0.in-not
net x-pos-limit sscii.0.gpio.1.in-not
net stop sscii.0.gpio.11.in-not

and then use signal names for actual connection:

net x-pos-limit => axis.0.pos-lim-sw-in
net x-neg-limit => axis.0.neg-lim-sw-in

if wiring changes, i can just edit the first net definition. BUT! i
also have a pyvcp panel with LEDs  showing inputs status. and i can't
just write in posgui.hal

net led-in0 sscii.0.gpio.0.in-not => pyvcp-led0

because sscii.0.gpio.0.in-not was already named x-neg-limit! so i'm
forced to use x-neg-limit name here which ruins routing localization
attempt...

am i missing something? is there a way to make a connection without
referring to a signal name which was given to it before?

/dmtiry

------------------------------------------------------------------------------