Norbert [DISPLAY] INCREMENTS is used only by GUIs (as the motion controller does not keep track of a jog increment) Guis are free to do what they wish with the data.
When you say degrees are not allowed, do you mean in AXIS? Chris M ________________________________ From: Niemand Sonst <[email protected]> Sent: January 2, 2019 12:21 PM To: [email protected] Subject: [Emc-developers] [DISPLAY] INCREMENTS why not degrees allowed? Hallo, as I am just rewriting gmoccapy, I falled over the INCREMENT section in INI File. /INCREMENTS = 1 mm, .5 in, …//- Defines the increments available for incremental jogs. The INCREMENTS can be used to override the default. The values can be decimal numbers (e.g., 0.1000) or fractional numbers (e.g., 1/16), optionally followed by a unit (cm, mm, um, inch, in or mil). If a unit is not specified the machine unit is assumed. Metric and imperial distances may be mixed: INCREMENTS = 1 inch, 1 mil, 1 cm, 1 mm, 1 um is a valid entry. / Why are degrees (°) not allowed? Norbert _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers