Mel, The requirement can be found in CSA C22.2 No. 950/UL 1950 (Bi-National Standard) in Annex NAE, Clause No. 3.2.4.
Maximum cord length: 4.5 m Minimum cord length: 1.5 m (with some exceptions) These are North American deviations based on the National Electrical Code and the Canadian Electrical Code. Best regards, Dave EMC Corporation 171 South Street Hopkinton, MA 01748 508-435-1000, x7518 508-435-5067 (fax) loru...@emc.com (email) ----------------------[Reply - Original Message]---------------------- Sent by:mjen...@yak.cray.com (Mel Jensen) All; Can anyone provide guidance as to allowable length(s) for attached power cords for ITE equipment? Either e-mail or post responses. And thank you in advance for any and all help. Mel Jensen, P.E. Cray Research, Inc. TEL:715-726-8374 1050 Lowater Rd. FAX:715-726-6715 Chippewa Falls, WI 54729 EMAIL:mjen...@cray.com ____________________________________________________________________________ ___ =====================================================================