Hi All,
I wasn't going to reply to this but have just read EN50130-4:1995 for the 
umpteenth time and section 12.3.1, which relates to EFTB testing using 
61000-4-4, says:
"For wall and ceiling mounted equipment, follow the procedure for floor 
standing equipment, but with the equipment arranged with it's normal mounting 
surface 0.1 m. from the earth reference plane."

EN50130-4 gives immunity requirements for components of fire, intruder and 
social alarm systems.

Hope this helps

Ian Ball
Dedicated Micros EMC Test Centre
UK

---------