Chris,

If my memory serves me well, EN60555-2 required measurement of THD vs.
complete/individual 40 harmonics' signature with individual limits required
by  -3-2.  This results in the mandatory re-testing.

Vitaly  Gorodetsky
Compliance Engineer                     Direct: (818) 678-3840
Canoga Perkins Corp.                    Main:   (818) 718-6300
20600 Prairie Street                    FAX:    (818) 678-3740
Chatsworth, CA 91311-6008                               e-mail:
vgorodet...@canoga.com <mailto:vgorodet...@canoga.com>  

The suitability of this information for making decision is solely with the
reader


        -----Original Message-----
        From:   Colgan, Chris [SMTP:chris.col...@tagmclarenaudio.com]
        Sent:   Tuesday, December 19, 2000 1:51 AM
        To:     'Emc-Pstc' (E-mail)
        Subject:        EN61000-3-2 A14


        Sorry for another post about this amendment but....

        Can anyone confirm that the limits for class A equipment are the
same as
        those in EN60555-2 and that the measurement techniques are the same?

        That is, if I have equipment (not TV or PC) conforming to EN60555-2
can I
        say that it conforms to EN61000-3-2 + A14 without any further
testing?

        Have a great holiday

        Regards

        Chris Colgan
        Compliance Engineer
        TAG McLaren Audio Ltd
        The Summit, Latham Road
        Huntingdon, Cambs, PE29 6ZU
        *Tel: +44 (0)1480 415 627
        *Fax: +44 (0)1480 52159
        * Mailto:chris.col...@tagmclarenaudio.com
        * http://www.tagmclarenaudio.com



        **************************************************************  
                   Please visit us at www.tagmclarenaudio.com
        **************************************************************

        The contents of this E-mail are confidential and for the exclusive
        use of the intended recipient. If you receive this E-mail in error,
        please delete it from your system immediately and notify us either
        by E-mail, telephone or fax. You  should not  copy, forward or 
        otherwise disclose the content of the E-mail.

        TAG McLaren Audio Ltd
        The Summit, 11 Latham Road
        Huntingdon, Cambs, PE29 6ZU
        Telephone : 01480 415600 (+44 1480 415600)
        Facsimile : 01480 52159 (+44 1480 52159)

        **************************************************************  
                   Please visit us at www.tagmclarenaudio.com
        **************************************************************

        -------------------------------------------
        This message is from the IEEE EMC Society Product Safety
        Technical Committee emc-pstc discussion list.

        To cancel your subscription, send mail to:
             majord...@ieee.org
        with the single line:
             unsubscribe emc-pstc

        For help, send mail to the list administrators:
             Jim Bacher:              jim_bac...@mail.monarch.com
             Michael Garretson:        pstc_ad...@garretson.org

        For policy questions, send mail to:
             Richard Nute:           ri...@ieee.org
        

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Jim Bacher:              jim_bac...@mail.monarch.com
     Michael Garretson:        pstc_ad...@garretson.org

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org

Reply via email to