All, What are the exact requirements for End of Line testing and do they differ from country to country. We currently subject products to the following tests: 1. Earth Bonding at 25A (resistance to be less than 0.1 Ohms) 2. Dielectric strength test of 2.1KVDC for 2 seconds. 3. Insulation resistance test of 500VDC (resistance to be greater than 10MOhms). Question -------- Is this last test mandatory for product compliance in UK/Europe/USA/Rest of the World? Kind Regards Tony Reynolds Principal Compliance Engineer Pitney Bowes Ltd The Pinnacles Harlow Essex CM19 5BD Tel +44 1279 449479 Fax +44 1279 449118 E-Mail: reyno...@pb.com www.pitneybowes.com
------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: jim_bac...@mail.monarch.com Michael Garretson: pstc_ad...@garretson.org For policy questions, send mail to: Richard Nute: ri...@ieee.org