Obviously, I was not clear. This is an unintentional radiator. The rf signal is radiated internally, but any external emissions are unintentional.
Richard Woods ---------- From: Helge Knudsen [SMTP:h...@jyske-emc.com] Sent: Thursday, November 16, 2000 5:35 AM To: emc-p...@majordomo.ieee.org; wo...@sensormatic.com Subject: Vedr.: ITE Emissions above 1 GHz Hello Richard, Is the device a "blue tooth" using wireless radiation to communicate with other devices, if yes the device is a subjet for the R&TTE directive. You may use the ETSI standards: EN 301 489-3 V1.2.1 (2000-08) Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 40 GHz and EN 300 440-2 V1.1.1 (2000-07) Electromagnetic compatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2: Harmonized EN under article 3.2 of the R&TTE Directive Those standards may be downloaded free of charge from www.etsi.org. NOTE:They are not harmonized yet! If it not is used for wireless communication then the EN 55022 still shall be used for showing complience with the EMC Directive. Best regards Helge Knudsen Delta Electronics Testing, EMC Venlighedsvej 4, DK-2970 Hoersholm Telephone : +45 45 86 77 22 Fax : +45 45 86 58 98 >>> <wo...@sensormatic.com> 15-11-00 22:10 >>> I have an Information Technology device that intentionally generates and uses 2.45 GHz signals. EN55022 does not provide limits above 1 GHz. Is there another harmonized EN that can be applied for spurious emissions above 1 GHz? If not, will this product have to be submitted to a Competent Body? Richard Woods ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: jim_bac...@mail.monarch.com Michael Garretson: pstc_ad...@garretson.org For policy questions, send mail to: Richard Nute: ri...@ieee.org ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: jim_bac...@mail.monarch.com Michael Garretson: pstc_ad...@garretson.org For policy questions, send mail to: Richard Nute: ri...@ieee.org