Some Hi-pot testers have the ability to set a minimum leakage current
expected which sets the alarm off if the unit being tested is switched off
or otherwise disconnected.
 
Our UL inspector expects to see a calibration log for the Hi-pot tester.
 
It is quite easy to build a simple fixture to test a hi pot - I'll happily
email a pdf to anyone interested.
 
Chris
 

-------------------------------------------