ENV 50140 is superseded by EN 61000-4-3:1996, and therefor not valid anymore
regarding fulfilling the EMC requirements in EU.

Best regards
Amund Westin, Oslo/Norway




-----Opprinnelig melding-----
Fra: [email protected]
[mailto:[email protected]]På vegne av [email protected]
Sendt: 6. november 2001 21:39
Til: [email protected]
Emne: Immunity standards equivalence?



Has EN 50140:94 (EMC/basic; radiated RF EM field immunity) been replaced by
EN61000-4-3('99)? Are they identical? At USD120, I want to confirm there's
some difference 'tween the two. Under the auspices of EN61326:97
(...measurement, control and laboratory equipment EMC), the former doesn't
appear to be mentioned.

Wm Flanigan
Standards Engineer
Ameritherm Inc
39 Main Street
Scottsville, NY  14546
[email protected]
1.716.889.9000
1.716.889.4030 (fx)


-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Michael Garretson:        [email protected]
     Dave Heald                [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    No longer online until our new server is brought online and the old
messages are imported into the new server.



-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Michael Garretson:        [email protected]
     Dave Heald                [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    No longer online until our new server is brought online and the old 
messages are imported into the new server.

Reply via email to