Howdy all,

Having been involved with power cords and cord sets for quite some time I
have never seen an advantage in using "Universal" cordage. Therefore, I
would be interested to hear from people what they have to say about their
usage of "Universal" cordage and what they have benefited from using it. I
am specifically interested in certification and material costs when using
"Universal" cordage versus HAR or UL/CSA certified cordage.  
  
Regards,
+=================================================================+
|Ronald R. Wellman                |Voice : 408-345-8229           |
|Agilent Technologies             |FAX   : 408-553-2412           |
|5301 Stevens Creek Blvd.,        |E-Mail: [email protected]|
|Mailstop 54L-BB                  |WWW   : http://www.agilent.com |
|Santa Clara, California 95052 USA|                               |
+=================================================================+
| "Common sense is the collection of prejudices acquired by age   |
|  eighteen." - Albert Einstein                                   |
+=================================================================+



-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: Monday, January 07, 2002 2:21 PM
To: Peter Merguerian; [email protected]
Subject: Re: European and North American Cordage





Peter,
We used a HARSVT 3x18AWG 1.00mm2 "Universal"   linecord from Feller on the
Lexmark MarNet XLe External Network Adapter.  This had a Harmonized plus
UL/CSA-listed cordage.  I can't find my Feller catalog right now, and their
website (    http://www.feller-at.com/     ) doesn't say, but I think that
they
had HARSVT cordage in 16AWG and 14AWG, along with HARSJT cordage.

                                              John Barnes  Advisory Engineer
                                              Lexmark International



-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Michael Garretson:        [email protected]
     Dave Heald                [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    No longer online until our new server is brought online and the old
messages are imported into the new server.

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Michael Garretson:        [email protected]
     Dave Heald                [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    No longer online until our new server is brought online and the old 
messages are imported into the new server.

Reply via email to