HI all, I have a question regarding performing conducted emissions on a wall mount power supply. When looking at EN 55022 test setup it shows EUT on tabletop with 80 cms from EUT to AMN and bundled cord between AMN and EUT. If you where testing a wall mount power supply does anyone feel that the specification supports letting you put an extension cable between wall mount power supply and LISN to meet this setup. In essence the question is, Does a wall mount power supply have to be tested plugged directly into the LISN.
By inserting the cable between supply and LISN you are adding inductance and results are a few dB better. Also you could argue that wall mount supply should be plugged into LISN to replicate actual usage. I know that I may have answered my own question but am interested if anyone else believes putting "extension" cord between LISN and wall mount supply is reasonable. As usual colleagues, thanks in advance for your thoughts. Sandy Mazzola Santo Mazzola Regulatory Engineer Symbol Technologies Inc 1 Symbol Plaza Holtsville, N. Y. 11742-1300 Phone: (631) 738-5373 Fax: (631) 738-3318 E-mail: mazzo...@symbol.com
BEGIN:VCARD VERSION:2.1 X-GWTYPE:USER FN:Mazzola, Sandy TEL;WORK:(631) 738-5373 EMAIL;WORK;PREF;NGW:mazzo...@symbol.com N:Mazzola;Sandy X-GWUSERID:MazzolaS END:VCARD BEGIN:VCARD VERSION:2.1 X-GWTYPE:USER FN:Mazzola, Sandy TEL;WORK:(631) 738-5373 EMAIL;WORK;PREF;NGW:mazzo...@symbol.com N:Mazzola;Sandy X-GWUSERID:MazzolaS END:VCARD