Hi all, When abnormal tests are performed against clause 5.3 of IEC 60950 3rd ed, do we have to measured the SELV voltage to be sure they are in the limits as defined in case of first default. I never seen reports where it's done, but I've performed tests where these voltage were outside the SELV values.
What is your opinion on this matter ? Thanks a lot for your answers, Pierre Selva eLABs (emc, safety, radio, eco-design - product regulations) 1 rue des Essarts 38610 GIERES - FRANCE e-mail : e.l...@wanadoo.fr ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: emc-p...@hypercom.com Dave Heald: davehe...@attbi.com For policy questions, send mail to: Richard Nute: ri...@ieee.org Jim Bacher: j.bac...@ieee.org All emc-pstc postings are archived and searchable on the web at: http://ieeepstc.mindcruiser.com/ Click on "browse" and then "emc-pstc mailing list"