In a message dated 11/12/2004 1:30:21 PM Central Standard Time,
tdonne...@act-sys.com writes:




I am looking for a HIRF test facility that can handle 3000 V/m from 2 to 12
GHz. I have to test from 10 kHz to 40 GHz but at lower levels. I have a fairly
large system for testing so I am leaning towards a reverb chamber to get
around small antenna beam width issues. 

Any leads for a test house, or advice on doing this testing is appreciated.

Thanks,
Tom Donnelly 
Smiths Aerospace Actuation Systems 
973-428-9898 x445
tdonne...@act-sys.com 







Hi Tom,

you may want to talk to the folks at PAX River Navel Base. Start with Diane
Kempf.

If your needs are closer to Christmas, I should be able to do that.

Sincerely

Derek Walton
L F Research.
---------------------------------------------------------------- This message
is from the IEEE Product Safety Engineering Society emc-pstc discussion list.
Website: http://www.ieee-pses.org/ 

To post a message to the list, send your e-mail to emc-p...@ieee.org 


Instructions: http://listserv.ieee.org/listserv/request/user-guide.html 


List rules: http://www.ieee-pses.org/listrules.html 


For help, send mail to the list administrators: 


Ron Pickard: emc-p...@hypercom.com Scott Douglas emcp...@ptcnh.net 


For policy questions, send mail to: 


Richard Nute: ri...@ieee.org Jim Bacher: j.bac...@ieee.org 


All emc-pstc postings are archived and searchable on the web at: 


http://www.ieeecommunities.org/emc-pstc 


Reply via email to