Hi Everyone,

'Been writing again, this time comparing single and multiple turn 
ferrites. This month's Technical Tidbit on my website discusses 
characteristics of ferrite cores with single or multiple turn windings 
and the conditions where each performs best based upon measured data.

Abstract: Ferrite chokes are often used to reduce currents due to ESD 
and to provide series impedance to suppress common mode currents that 
can cause EMC emissions problems. Data is presented to show how an ESD 
current is affected by single pass and multiple turn ferrite chokes. 
The data is extended to predict how the chokes affect EMC emissions. 
Recommendations are inferred from the data as to when to use single 
pass or multiple turn windings on ferrite cores.

The link to the article is the picture of the experimental test setup 
at the bottom of the home page at http://emcesd.com .
-- 

     ___          _       Doug Smith
      \          / )      P.O. Box 1457
       =========          Los Gatos, CA 95031-1457
    _ / \     / \ _       TEL/FAX: 408-356-4186/358-3799
  /  /\  \ ] /  /\  \     Mobile:  408-858-4528
|  q-----( )  |  o  |    Email:   [email protected]
  \ _ /    ]    \ _ /     Website: http://www.dsmith.org



This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/listserv/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas             [email protected]
     Mike Cantwell            [email protected]

For policy questions, send mail to:

     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to