I have used and enjoyed instruments from Elgar for this purpose (but not an
inexpensive solution).

luck,
Brian 

 > -----Original Message-----
 > From: emc-pstc@LISTSERV.IEEE.ORG 
 > [mailto:emc-pstc@LISTSERV.IEEE.ORG]On
 > Behalf Of John Woodgate
 > Sent: Friday, October 07, 2005 9:02 AM
 > To: emc-p...@ieee.org
 > Subject: Re: harmonic distortion testing
 > 
 > 
 > shbe...@rockwellcollins.com wrote (in 
 > <OF0CC42EDE.C55A13B6-ON85257093.00530A02-85257093.00536847@ro
 > ckwellcollin
 > s.com>) about 'harmonic distortion testing', on Fri, 7 Oct 2005:
 > >Please forgive my ignorance of international, commercial regulatory 
 > >standards, but I have questions on harmonic distortion 
 > testing (power 
 > >feeds).  Could someone point me to test equipment that 
 > performs these 
 > >tests?
 > 
 > California Instruments, for example.
 > -- 
 > Regards, John Woodgate, OOO - Own Opinions Only.
 > Deadlines are 90% of deadliness.
 > http://www.jmwa.demon.co.uk Also see http://www.isce.org.uk
 

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to emc-p...@ieee.org

Instructions:  http://listserv.ieee.org/listserv/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           emcp...@ptcnh.net
     Mike Cantwell           mcantw...@ieee.org

For policy questions, send mail to:

     Jim Bacher:             j.bac...@ieee.org
     David Heald:            emc-p...@daveheald.com

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to