On 2/10/2006, Richard Stone wrote:
Has anyone heard of PEE001 and PEE002 for Rad/Cond EMI in Brazil? Is it the same basic setup and test requirements as the EU's Cispr22? Hi Richard: What kind of equipment are you concerned with? The applicable EMC requirement (both emissions and immunity) for telecom equipment in Brazil is Resolution 237, dated November 2000. This standard borrows heavily from international standards such as CISPR 22, CISPR 24, K.21, and K.22, and the test procedures are mostly drawn from the IEC 61000 series. However, in some cases Brazil has altered some of the limits and has added tests that are specific to Brazil. Joe Randolph Telecom Design Consultant Randolph Telecom, Inc. 781-721-2848 (USA) [email protected] http://www.randolph-telecom.com <http://www.randolph-telecom.com/> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc